2. to validate if it's same problem between PFMF & linearity error abnormal ?
test conclusion
1. Vout is more sensitive to external field disturbance than Vref.
2. sensor is more sensitive to X axis external field disturbance.
3. A samples and B samples are some level on PFMF immunity. -> C5 broken cann't lead to poor PFMF immunity.
4. #6 - #10 are some level on PFMF immunity. -> linearity error abnormal are not lead to poor PFMF immunity . ? 由于#6-#10经过temp cycle,所以不确定linearity error是否异常,所以需要进一步Validation 4.' -> it maybe improved for immunity to PFMF after thermal treatment. (#6 - #10 went through Characterization@25C test and thernal drift @-40C to 105C test)
5. continual validation action 3&4
3. to validate if thermal treatmeet would improve PFMF immunity?
A1 & B1 go through temp cycle, and then do PFMF test, compare the two results.
A2, A3 & B2 ,B3 go through thermal shock, and the do PFMF test ...
4. to validate if thermal treatmeet would improve linearity error?
to do list: retest the linearity error of C&D samples, 5pcs totally.
if all is OK --> then No.
if results aren't change --> then No.
if no, perform thermal shock and then do temp cycle again.
ref to CFU experience, temperature cycle would not improve linearity error abnormal, but thermal shock will.